CC4-0808AL

CC-Link integrated I/O, 8 inputs and 8 outputs, NPN, 0.5A, input delay ≤1.5ms

Small in size, compact structure, only 102×72×25 mm

Supports digital input delay, can filter out clutter within 1.5ms

Spring-loaded pluggable terminals for quick wiring

Simple configuration setup, can be cascaded, supports mainstream CC-Link master stations such as Mitsubishi

Compare

Interface Parameters

Bus connection methodSpring-Clamp Terminal
Bus protocolCC-Link
Data transmission mediumCC-Link dedicated cable (3-core shielded twisted pair cable)
Transmission rate10 Mbps/5 Mbps/2.5 Mbps/625 kbps/156 kbps
Transmission distance<= 100 m/ <= 160 m/ <= 400 m/ <= 900 m/ <= 1200 m

Technical Parameters

Operating temperature-10 ... 60 °C
Storage Temperature-20 ... 75 °C
Power Supply.. 36 V DC
Weight150 g
Dimensions102 x 72 x 25 mm
Protection ratingIP20
Relative Humidity95 %, non-condensing
Power Connection MethodSpring-Clamp Terminal
Configuration methodvia master

Digital Input

Rated voltage24 V DC (±25 %)
Number of Signal Points8
Signal TypeNPN
Input Current4 mA
Isolation withstand voltage500 V
Channel indicatorGreen LED
"0" Signal Voltage.. 30 V
"1" Signal Voltage-3 ... +3 V
Input Filter1.5 ms
Isolation methodOptocoupler Isolation

Digital Output

Rated voltage24 V DC (±25 %)
Number of Signal Points8
Signal TypeNPN
Load TypeResistive load, inductive load
Rated Current per Channel0.5 A
Port ProtectionOvervoltage and overcurrent protection
Isolation withstand voltage500 V
Channel indicatorGreen LED
Isolation methodOptocoupler Isolation