Multiple thermocouple signal types selectable; DC 300V withstand voltage between signal input channels, suitable for grounded probes
The front panel supports channel switching, parameter setting, and status monitoring, intuitive and easy to operate
Features measurement display, control output, retransmission output, output time accumulation, sensor wire break detection, and more
Multiple PID control algorithms available, with auto-tuning function
| Power Supply Voltage | DC 24V |
| Power consumption | 2W in no-output state; max. total power consumption 40W with 24V transistor output; max. total power consumption 6W with 4~20mA output |
| Operating Temperature | 0~50℃ |
| Relative Humidity | <85%RH |
| Storage Temperature | -10℃~60℃ |
| Module Size | 47×123×110.5mm |
| Weight | 400g |
| Housing Material | Housing and panel base frame: PA66 (flame retardancy UL94 V-0) |
| Front Film Material | PC film and PEM silicone rubber keypad |
| Master Output Type | Transistor open collector output or 4~20mA selectable |
| Transistor Output Capacity | @25℃ DC 24V max. 100mA; derated to 50mA at high temperature; withstand voltage 100V |
| Current/Voltage Output Load Capacity | 4~20mA load < 500Ω; linearity 0.2% |
| Display Update | 2 times per second per channel (sampling rate greater than 80 times per second) |
| Insulation Resistance | Input, output, power supply to housing > 20MΩ |
| Electrostatic Discharge (ESD) | IEC/EN61000-4-2 Contact±4KV/Air±8KV perf.Criteria B |
| EFT/Burst Immunity | IEC/EN61000-4-4 ±2KV perf.Criteria B |
| Surge Immunity | IEC/EN61000-4-5 ±0.5KV perf.Criteria B |
| Voltage Dips and Short Interruptions Immunity | IEC/EN61000-4-29 0%~70% perf.Criteria B |
| Power Failure Data Retention | 10 years, EEPROM write cycles greater than 10 billion |
| Isolation Voltage | Signal input to power supply: 500V AC, 1 min |