Supports high-speed EtherCAT Communication, CoE (CANopen over EtherCAT) compliant with CiA 402
Max. current 6 A, supports closed-loop control with incremental Encoder for more precise positioning and smoother Run
Digital display button replaces traditional DIP switch, making Parameter Setting more intuitive and convenient
| Interface type | 2 x RJ45 |
| Brake interface | Direct brake connection, no additional Relay control required |
| Output Current | 1. 0.5 ... 6 A |
| Rated voltage | 20 ... 80 V DC, 18 ... 50 V AC |
| matching motor | Closed-loop, frame size 60 and below |
| Encoder Interface | Incremental Quadrature Encoder |
| Encoder resolution setting | 0 ... 65535 |
| Optically isolated inputs | 4-channel common-anode 24 V Inputs |
| Opto-isolated outputs | 2-channel photoelectrically isolated Outputs: alarm, in-position and General Purpose Output |