The Solidot C3 series valve terminal is available with two interface types, M12 and RJ45; C3P is the sub-series that uses the RJ45 network port. The product is delivered as a complete unit that integrates the solenoid valve assembly, bus communication and output control, and supports mainstream industrial protocols such as PROFINET, EtherCAT, EtherNet/IP and CC-Link IE Field Basic. Valve slices, valve types and air path structures can be configured to suit the project, making it suitable for automated production lines that place demands on the number of pneumatic control points, deployment efficiency and ease of maintenance.
Network port access, cascaded networking
The bus side has two RJ45 interfaces. Two valve terminals can be connected in series on the same bus via the dual network ports, reducing the number of master ports occupied.

Air path configuration combined as needed
4 to 24 valve slices are available, and valve slices come in two widths, 10 mm and 14 mm. The valve functions cover eight valve types in total: 5/2-way single solenoid, 5/2-way double solenoid control, 3/5-way (closed center / exhaust center / pressure center) and 2x 3/2-way; blank valve slices can also be specified in the model.
The pilot method supports switching between internal and external pilot. Supply ports 1, 3 and 5 can be assigned to pressure zones by valve slice, so a single valve terminal can contain air path zones with different supply pressures to meet multi-pressure process requirements.
The solenoid valve uses a bottom plug-in direct connection structure, so replacing a valve slice does not require removing the air path connectors.
Customized installation
Online selection can be performed on the Solidot website under "Fieldbus Valve Terminal - C3 Series"; once the valve terminal model has been generated it can be copied, making it easy for customers to record and inquire about.

The model is assembled from its segments in a fixed order, in which the solenoid valve and valve connector segments are written in the actual assembly sequence. Different valve slices on the same valve terminal can be fitted with different valve types and different connector specifications, so the air path interface combinations are correspondingly flexible.
Channel diagnostics, controllable on network loss
Outputs are sent in bytes; one byte corresponds to 4 double solenoid valve slices, and bit operation is also possible. When fully equipped with 24 double solenoid valve slices, 6 bytes are occupied, for a total of 48 channels.
Each of the 48 channels has short circuit and over temperature diagnostics; the diagnostic bits can be read by the master, and faulty channels can be located remotely. The output behaviour after a communication interruption can be selected as clear output, output valid or hold last output value; the factory default is to clear all outputs.
The power supply side uses a 5-pin push-in terminal; the system power supply and load power supply are configured separately, with reverse connection protection and field-side surge protection, and an isolation withstand voltage of 500 V.
The above is an introduction to the Solidot C3P Fieldbus Valve terminal.