The Solidot integrated I/O module EI3 series products use an Industrial Ethernet bus interface for EtherNet/IP and are EtherNet/IP slave devices with a standard I/O Architecture. They are compatible with EtherNet/IP networks from multiple vendors and are widely used in industries such as panel and 3C. Their horizontal design is only 35 mm high, making them suitable for installation in locations with limited depth.

Solidot integrated I/O module EI3 series representative modelEI3-0032A
This series includes multiple products. Refer to the following table for model selection:
Single-wire digital I/O | ||
1 | EtherNet/IP Integrated I/O, 32 inputs, NPN&PNP compatible, Screw terminal | |
2 | EtherNet/IP integrated I/O, 16 inputs 16 outputs, NPN, 0.5 A, screw terminal | |
3 | EtherNet/IP Integrated I/O, 16 inputs 16 outputs, PNP, 0.5 A, Screw terminal | |
4 | EtherNet/IP integrated I/O, 32 outputs, NPN, 0.5 A, screw terminal | |
5 | EtherNet/IP Integrated I/O, 32 outputs, PNP, 0.5 A, screw terminal | |
The Solidot integrated I/O module EI3 series products feature input compatibility. The digital input signals are compatible with both NPN and PNP. They use a 100 Mbps industrial Ethernet port, offering faster speed and simple configuration, and support all major EtherNet/IP Masters.

The innovative channel indicator design is positioned close to the channel, making the channel status clear at a glance and simplifying inspection and maintenance.

The module consists of a terminal Dust cover, rotary switch, system LED & indicator, module label, DIN Rail Mounting Slot, Fieldbus interface, channel type Marking, channel indicator & marking, terminal blocks, and Latch.

The rotary switch allows convenient IP address setting. The specific method is shown in the figure below:

Setting value (decimal) | IP address setting method |
000 | BOOTP-based setting |
.. 254 | Set the lower byte of the IP address. Use "×100" for the hundreds digit, "×10" for the tens digit, and |
255 ... | When the rotary switch is set to 255 or above, the module starts with the previous startup mode and parameters after power-on. |
The factory setting of the rotary switch is "000". | |
1. Tool selection | |
Screwdriver specification: blade width 2 mm. | |
2. Rotary switch IP must be set with the power disconnected. If the IP address needs to be changed during communication, the new settings must be followed by a restart of the | |
It is suitable for DIN 35 mm Rail mounting, uses screw terminals, and enables stable and quick wiring.

This concludes the introduction to the Solidot integrated I/O module EI3 series. Thank you for watching.